High Performance Soundproofing Underlayments for Reduce Floor Noise. Reduce Floor Noise to a whisper with our line of SSP High Performance Soundproofing Underlayments. Concerned about reducing impact and acoustical (airborne) sound transmission through hard flooring surfaces? Eliminating impact and acoustical noise problems between floors in multi- story construction is another sign of a quality installation and a feature that clients, residential and commercial will appreciate. This includes, but is not limited to condominiums, apartments, single family homes, office buildings, RV’s, hotels and schools.

Protecto wrap: www.protectowrap. If a crack isolation membrane is not used.

To address these concerns, Super Soundproofing. The line includes: SSP- TL: for ceramic and natural stone tile. SSP- FL: for engineered hardwood, parquet, and laminate flooring. SSP FL Plus: same qualities as Super Soundproofing.

It is constructed of cross- linked poly- olefin foam sheet combined with an aggressive rubberized adhesive and a polyester mesh fabric. Designed for use with ceramic and natural stone tile, Super Soundproofing. It also has superior moisture resistant properties that make it the most comprehensive underlayment product for ceramic and natural stone available. And like its counterparts in the Super Soundproofing. Designed for use with engineered wood plank, wood parquet and laminate floors, it should be used where sound- control is required, specified, or desired. Super Soundproofing. Super Soundproofing.

The cross- linked poly- olefin foam top sheet makes an excellent bonding surface for approved wood flooring adhesives and will not dry out or decay with time. It also contains no V. O. C’s and is environmentally safe. The Super Soundproofing. The Super Soundproofing. It is designed to seal subfloors that have up to 8 lbs. The Sealer- Primer also seals porous and dusty surfaces, which improves adhesion spread rates and long- term bond aging.

Designed for easy roller application, it forms a tough water resistant film over the substrate surface when applied properly. The entire Super Soundproofing. When sound control, crack suppression, and moisture resistance are your concern, turn to the flooring membrane sound control professionals at Super Soundproofing. The membrane is tacky on the bottom providing superior adhesion to concrete, steel and wood substrates. The cross- linked poly- olefin foam top sheet makes an excellent bonding surface for approved wood flooring adhesives.

Interior Wood or Vinyl Floors Interior. Protecto Wrap Anti-Fracture Membrane. Load bearing waterproofing/crack isolation membrane that DOES NOT. Protecto Wrap AFM Anti-Fracture Membrane. AFM® Anti Fracture Membrane. Peel and Stick Crack Isolation & Waterproofing Tile and Flooring Underlayments. AFM Anti Fracture Membrane is made. See Protecto Wrap. FOR IMMEDIATE RELEASE Protecto Wrap Reduces Floor Noise with. Professional flooring installers demand a crack isolation membrane designed. Peel & Stick. A peel and stick membrane uses a positive. Protecto Wrap Stucco Tape. AFM® Anti Fracture Membrane. Peel and Stick Crack Isolation & Waterproofing. Stress-relieving barrier membrane for concrete. Protecto Wrap Company.

Ditra Crack Isolation Membrane

Protecto Wrap Crack Isolation Membrane At Wood

Contact us for the approved adhesive list. SSP- FL contains no V. O. C’s and is environmentally safe. The cross- linked poly- olefin foam and its aggressive rubberized adhesive retain its flexibility throughout the floor’s life span and will not dry out or decay with time.

Protecto Wrap® Dal-CIM 500 EX Crack Protection Kit. The crack isolation and sound-reduction sheet membrane has a quick installation time with a. TEC releases HydraFlex waterproofing membrane. TEC releases fast-set version of its 1Flex Crack-Isolation. Schönox HPS North America Protecto Wrap Co. Tiledek is an outdoor anti-fracture roofing membrane designed for outdoor. Protecto Wrap Co.

Size: Available in 3. It may be applied to structurally sound and clean surfaces including: concrete, plywood, precast floor panels, OSB, Ceramic tile, terrazzo, natural stone, Portland based leveling and patching compounds, cement backer board, existing VAT, VCT and fully adhered vinyl floors. SSP- FL is approved for installation over radiant heated floors. Limitations: SSP- FL is not recommended for use on concrete floors where hydrostatic pressure is present or where Moisture Vapor Emissions Rate exceed 4 lbs.

Isolation Membrane For Concrete Cracks

SSP- FL cannot maintain the high sound control ratings when used with solid wood plank flooring or any “nail down” only wood floors. Gypsum type patches and levelers are not recommended. Super Soundproofing. Install New Hard Disk In Imac G5. NOTE: Use only approved wood flooring adhesives (Contact us for list).

Installation procedures and job site conditions must be in accordance with flooring manufacturer’s recommendations and NWFA installation standards or performance will suffer. INSTALLATION for Wood Floors.

Follow wood flooring manufacturers recommended installation instructions as to fully adhered or floating floor installation. Your wood flooring and SSP- FL membrane must acclimate to job site conditions before installation.

Concrete subfloors must be dry, clean and free of dirt, grease, wax, paint, oil or anything that would adversely affect adhesion of the material. Subfloors must be checked for excessive moisture. If subfloor moisture/vapor is higher than 4lb. Emissions, SSP- FL membrane cannot be used (see “Limitations”). Subfloors must be flat to 3/1. Leveling cements must be completely dry before membrane application.

Priming the subfloor: Always apply the Super Soundproofing. Cut the length approximately 1. Fold back half of the length of the roll back over the other half of the material. Score through the release liner only, taking care not to cut completely through membrane. Pull release liner away from membrane where scored. As the release liner is pulled away, hand- smooth the membrane to contact the primed subfloor.

Keep the release liner material close to the floor while pulling away, this will allow for a more controlled application of the membrane. Take note: there will be an immediate and aggressive bond of the membrane to the primed subfloor. Realignment of the membrane can be difficult once adhered to the subfloor. Waterproofing Applications: Installations requiring waterproofing characteristics must have a topical application of liquid anti- fracture and waterproofing membrane at the seams of the SSP- FL. Using a 3/8. Allow the liquid membrane to cure fully before installing the wood flooring. Approved Wood Adhesives: Approved wood flooring adhesives work well. Most latex and acrylic based wood floor adhesives which are compatible with foam sheeting are approved.

Contact Super Soundproofing. Super Soundproofing. Some water- based adhesives do not bond sufficiently to the membrane surface.) Spread the approved adhesive onto the adhered membrane in accordance with manufacturer’s recommendations for trowel size and open time. Adhesive flash time may be longer when used over SSP- FL than over concrete or wood subfloors due to the membrane’s non- porous construction. Continue to follow wood flooring manufacturer.

Test construction included 3/8. Test results were: Impact Insulation Class IIC 7. Sound Transmission Class STC 7. Test results with other subfloor configurations are available by contacting Super Soundproofing Company. Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor- Ceiling Assemblies using the Tapping Machine” ASTM E9. Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.”Install Video.

We can supply the complete line of Protecto. Wrap Products as well as other solutions – Call!